Hp p410 sata drives for mac

To avoid any hard drive performance problems, connect the primary hard drive to the connector on the system board labeled sata 0 or sas 0, depending on hard drive type. Rilo constantly reports at least 3 drives as overheated when they are not. This high performance sas raid controller provides high levels of reliability for hp servers through its support of 6 gbs sas. Retired products sold prior to the november 1, 2015 separation of hewlettpackard company into hewlett packard enterprise company and hp inc. Hp smartarray p410 and a supermicro onboard satasas intel controller. Hp 870658b21 smart array p824ip mr gen10 storage controller sata 6gb. Slot led blau aufleuchten lassen ctrl slot2 pd pd 2i. You can have monitoring and fan speed problems with random sata disks on that controller. Hp notebook pcs how to add serial ata sata drives to a windows installation this document describes installing native serial ata sata drives on a computer that is using windows vista. Overview the hp smart array p812 is hps 24 port serial attached scsi sas raid controller with pci express pcie. Support for sas and sata hot plug sff midline mdl drives. Storage controller, hp smart array p410 sassata raid 0,1,10. Hp proliant smart array sassata event notification service for. Continue with step 3connecting the power and data cables on page 9.

Up to 12tb of total internal storage with 24 x 500gb sff sata hard drives up to 7. P410i smart array controller sata drive recommendations of. I just looked up the specs of the drive wd30efrx and it shows to be a 6gpbs sata drive but i do remember hp documentation stating any sata drive on a p410 controller will run at 3gbps. When i attach a samsung 256gb pro ssd it only connects at 1. The physical drive details are also similar heres the detail from an hp drive. Server hardware is a significant investment for any jp. The most current 20 version of the p410 quickspecs lists 4tb sata drives as supported. The hp raid controller will recognize the respected drives. Hi i like to confirm seagates st8000as0002 8tb hard drives can be used in raid5 in your hp smart array p410 raidcontroller, meaning the disks will not be kicked out of the array, etc. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement.

The same sata shows up as failed on bay 4 which was recently vacated by the failing drive however that bay is assigned to the array so it may be having an issue with it being sata vs. To expand the micro server even more, i decided to grab an hp smartarray p410 raid controller for peanuts. Hp proliant microserver gen8 sassata raid controller. As these drives use shingled magnetic recording smr it might become tricky once the raidarray needs to. Hp sas expander card connected to an hp sa p410 or hp sa p410i will require sas. P410i smart array controller sata drive recommendations of known.

Connect the opposite end of the data cable to the system board or controller card. Crucial memory and ssd upgrades 100% compatibility guaranteed for lenovo thinkstation p410 free us delivery. Ive updated my hp dl380 g6 8 bay sff standard stuff with the embedded p410i 512mb bbwc. This is prerequisite for the hp array configuration utility acu as the acu is run from the hp smh. Hp proliant dl165 g7 server maintenance and service guide. This way it will just present the drives through to the os as if they were normal dumb drives. Controller mac with a triplespeed ethernet transceiver. Hi i like to confirm seagates st8000as0002 8tb hard drives can be used in raid5 in your hp smart array p410 raidcontroller, meaning the disks will not be kicked out of the array, etc i like to attach 8 hard drives so 56000 gib will be available to my home cloud server. Hp smart array p410i1g fbwc controller storage controller raid sata 3gbs sas 6gbs pcie 2. Hp smart array p410256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410256mb pcie2 int only manufacturer part number 462862b21 ps. Connect p410 controller in a ml3709 g5 server to sata drives.

In the device configuration menu, select the raid as the sata device mode. Users can then configure or maintain the detected and supported devices such as hp proliant smart array controllers, hp proliant integrated smart array. Slide the hard drive into the selected bay until it snaps into place. Some computers, such as the hp z200 sff, hp z210 sff, and hp xw4000 series workstations, use four 632 screws. Hp 462919001 smart array p410 2ports pci express x8 sas raid controller. This will install the hp array drivers in preference to the supplied ones with whs 2011. Find answers to hp p410i performance problem with ssd from the expert community at experts exchange.

Hp p410 sassata controller not detecting sas drives, but. P420 smart array compatibility with 4tb sata drives. If you are installing multiple hard drives and using raid mode, connect one of the drives to the lowest numbered port sata0 or sata1, then connect the remaining drives to ports on the same controller. Please see the sata hard drive quickspecs for specific sata hard drive. Intel corporation patsburg 6 port sata ahci controller vmhba0. The sata drives were pretty fast hp smart array p410.

Desktop external hard drives portable external hard drives mac hard drives. That is odd as i could not get any drive to run at proper speed even when moving the smart array controller on any of the bus slots on the riser card. Hp p410 raid controller and sata drives not compatible. Hp dl380 g6 p410i ssd issue servethehome and servethe. The s3520bu33er 2bay raid enclosure with uasp enables you to build a secure external raid array with two 3. That kind of defeats the point of having the p410 in the first place though. Connect the power cable 1 and data cable 2 to the hard drive. Capacity given the increasing need for high performance and rapid capacity expansion, the sap410 controller offers. Hp p410i performance problem with ssd solutions experts. And will the p420 support 11 physical drives 1 x 500gb, 6 x 3tb, 4 x 4tb, all sata lff each drive as a single raid 0 lun 11 luns. Hard drives st2000dm0011er164 manufacturer seagate heads 16 cylinders 243,201 tracks 62,016,255 sectors 3,907,024,065 sata type sataiii 6. Hp smart array p410512 bbwc 2ports int pcie x8 sas controller. Hp and compaq desktop pcs about sata hard drives and.

Being a small company, we have scanty budget, but also flexibility. Hp smart array p410 controller hewlett packard enterprise. Works perfectly going from an internal sas port on an hp p410 controllers to an external 12 bay enclosure. I could either use the p410 or maybe an alternative 6g controller adaptec, lsi, ibm, etc. I like to attach 8 hard drives so 56000 gib will be available to my home cloud server. Does this mean that the p420 doesnt support 4tb drives or is this just badly worded. Now, just having a single configuration that works, i have a way forward, however buying a whole bunch of small old conroller samsung ssd doesnt seem the. We have a small server room, but the thunderous noise from a bunch of these would have disturbed the office. Quickspecs hp smart array p410 controller standard features da 201 worldwide version 27 december 3, 20 page 5 retired. Sas the failing drive also shows as failed on bay 5 where before it said eminent failure. Sata 1 to 5 hard disk adapter card motherboard sata port multiplier.

Search hpe support center drivers for hpe smart array p410. Just make sure youre on the latest smart array firmware and youre good to go. Here are some details about the pi itself from the same show config detail. Hp smart array p410 and seagate st8000as0002 hewlett. This is for the hardware guys, i have installed an ssd drive to a p410i raid controller and the io is awful does not gets more than 61mbs where this should be around 500mbs, i have changed a lot of settings on the controller, disable cache and nothing makes any difference. The advantage of p400 is that it does not require a software key for raid 6 like the p410 and newer ones do. One has a pair of hp oem 500gb sata drives in a raid1 array for a 40gb c. On some motherboards the sata ports are color coded. Media access controller mac with a triplespeed ethernet transceiver. Smart array cache module, 256 mb smart array p212, p410. Hp smart array p812 controller onboard expander firmware was updated to version 3. Hp has an expander card but the online specs are pretty weak, so it. Use hp sas disks with smart array p410 raid controllers.

The seller contacted me immediately and resolved the issue. Next, install the hp systems management homepage hp smh. After discovering the cache module was faulty, the card fired right up and the added sas. Storage controller, nonhot plug and cold plug sata models, hp smart array b110i sata raid. I even installed an hp raid card and used that for the sata drives that i had kicking around but that didnt help either. Hp satasas hard drive and solid state drive installation. Computers built for windows xp use nativeati technology to control hard drives, while windows vista uses native serial ata sata technology. I should mention ive checked the ilo and the motherboard firmware is up to date. P420 smart array compatibility with 4tb sata drive. If your computer uses an ssd primary drive, make sure that ahci is selected. The p410 and p410i are functionally equivalent, as mentioned by kissmyasthma above. You need a controller that supports sata at 3gbps sas at 6gbps. My earlier comment was incorrect namely, on the actual final oct firmware 6.

Hp p410i raid controller, mix and match sata and sas. Hp smart array p controller quickspecscpdf sata drives will downshift speed to 3. Moving this to the servers section and there will be more people in there with experience of this raid card as its common in vintage proliant servers. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. So, i just upgraded our hp proliant dl120 g7 with a p410512mb sassata controller and it wont detect our sas drives seagate 2tb, and gives a yelloworange light on them, but when i throw in a sata drive seagate 500gb, the light turns blue and it. I want to put in a couple of hp 500gb sata drives for use as my win 2008 r2 raid1 boot array in a hyperv box. Hp proliant smart array sas sata controller driver for windows server 2012. I am thinking of just looking for the drive trays on ebay and throwing in some wd drives. Hp notebook pcs how to add serial ata sata drives to a. Smart array p410 and sata drives connection speed issue. After the os had installed, i then updated the p410 smart array controller drivers. I am proposing to purchase qty 2, 7 sata port controllers and am going to build my own power cable using hp pn 463184002 spare 514217001.

81 983 633 856 982 1413 974 969 1348 1224 517 580 1057 943 430 530 892 947 1459 1351 434 383 417 582 979 985 1361 1099 1096 410 1256 1048 993 636 881 873 1077 1203 675 1283 726 962 721 1231 710